ChartVoyant Developers
Markdown

Clinical Interfaces & Exports

HL7 v2 interfaces

NewTurned on per interface

Lab results, radiology reports, and hospital admit, discharge, and demographic messages, sent to one practice over HTTPS by a lab, an imaging center, a hospital, or an interface engine. ChartVoyant answers every authenticated, well-formed message with an HL7 acknowledgment, files matched results to the chart for a clinician to review, and never creates or merges a patient.

POST https://chartvoyant.com/api/v1/interop/hl7/{interfaceId}

At a glance

StatusDeployed in production on October 29, 2026. Each interface is turned on individually, for one practice, once its onboarding is complete: agreements, a synthetic test run, independent security testing, and the practice's go-ahead.
EndpointPOST https://chartvoyant.com/api/v1/interop/hl7/{interfaceId}, one message per request. ChartVoyant assigns the interface ID when it sets up your feed.
StandardHL7 v2 in the pipe-delimited ER7 encoding. Version 2.5.1, or 2.3 through 2.5.1 on an interface set up with the tolerant profile.
TransportHTTPS, HL7 over HTTP style: the request body is the raw message, sent as x-application/hl7-v2+er7 or application/hl7-v2, and the ACK comes back in the response body. MLLP and SFTP are not available.
AuthenticationAn HL7 sender key that can deliver to one interface and do nothing else, or a SMART Backend Services token that carries system/hl7v2-ingest. See Authentication.
MessagesORU^R01 for lab and radiology results; ADT^A01, A03, A04, A08, A11, A13, A28, and A31 for hospital events and demographics. An A40 merge becomes a notice for staff and never merges charts.
Limits2 MiB per message. 20 messages per second and 600 per minute for each interface.
Where data landsOne practice per interface. A result files only to a patient matched with certainty, and is marked not yet reviewed until a clinician reviews it.

How an interface goes live

The receive endpoint, result filing, the review desk, and hospital event notices run in production. Each interface carries its own approvals before it takes a message: an interface agreement, a business associate agreement (and one for any intermediary in the path), the message types it may send, independent security testing that covers this endpoint, and the practice's go-ahead. Testing runs first on a separate interface in a ChartVoyant sandbox office, with processing ID T and synthetic messages, and it needs the same approvals on file.

Send a message

Synthetic values throughout. Use carriage returns between segments; line feeds are accepted too, and the strict profile notes them with a warning. Use the MSH-3 to MSH-6 values and the processing ID agreed when your interface is set up.

POST https://chartvoyant.com/api/v1/interop/hl7/INTERFACE_ID
Authorization: Bearer cvk_YOUR_HL7_SENDER_KEY
Content-Type: x-application/hl7-v2+er7

MSH|^~\&|SYNLAB|SYNLAB-CLEVELAND|CHARTVOYANT|EXAMPLE-PRACTICE|20261031101500-0400||ORU^R01^ORU_R01|SYN000123|T|2.5.1
PID|1||SYN-000123^^^SYNLAB^MR||ZZTEST^ALPHA||19700101|F
ORC|RE|PLACER_ORDER_ID|SYN-F-7781
OBR|1|PLACER_ORDER_ID|SYN-F-7781|4548-4^Hemoglobin A1c/Hemoglobin.total in Blood^LN|||20261030083000-0400|||||||||||||||20261031101000-0400||CH|F
OBX|1|NM|4548-4^Hemoglobin A1c/Hemoglobin.total in Blood^LN||6.1|%|4.0-5.6|H|||F

Response

HTTP/1.1 200 OK
Content-Type: x-application/hl7-v2+er7

MSH|^~\&|CHARTVOYANT|EXAMPLE-PRACTICE|SYNLAB|SYNLAB-CLEVELAND|20261031141501+0000||ACK^R01^ACK|ACK_CONTROL_ID|T|2.5.1
MSA|AA|SYN000123

The ACK swaps your sending and receiving application and facility, echoes your MSH-10 in MSA-2 and your MSH-11 and MSH-12, and stamps its own time in UTC. Error ACKs add ERR segments with an HL7 table 0357 code and a position, never a field value, so an ACK holds no patient data.

Acknowledgments

AA means the message is stored durably. Filing runs after the ACK, so a busy chart never holds your connection. ChartVoyant never sends AA and later a negative ACK: anything that cannot be filed after AA goes to a person at the practice, and you are not asked to resend.

AnswerWhenWhat to do
HTTP 401No credential, an invalid one, an unknown interface, or a credential that is not bound to that interface. All four look the same. No ACK; nothing stored.Check the key or token and the interface ID.
HTTP 400Malformed request: another content type, an empty body, or an interface ID that is not a UUID. No ACK; nothing stored.Fix the request.
HTTP 413Body over 2 MiB. No ACK; nothing stored.Send smaller messages.
200, MSA AAStored. An exact resend (same MSH-10, same bytes) gets the original answer and is not stored twice.Nothing.
200, MSA AEStored, but not usable as sent: required content missing (101), same MSH-10 with different content (205), an ADT with more than one PID, or one patient group in a multi-patient ORU failed.Correct it and resend under a new MSH-10.
200, MSA AE, 207Not accepted ("Message could not be accepted"): interface not on or paused, approval missing or lapsed, processing ID mismatch, rate limit reached, or temporary fault.Back off and resend the same message. If it continues, contact us.
200, MSA ARNot processed: unsupported message type/event (200, 201), unsupported version (203), or MSH-3–MSH-6 mismatch (204).Do not resend as is.

Generic 207 response

MSH|^~\&|CHARTVOYANT|EXAMPLE-PRACTICE|SYNLAB|SYNLAB-CLEVELAND|20261031141501+0000||ACK^R01^ACK|ACK_CONTROL_ID|T|2.5.1
MSA|AE|SYN000124
ERR|||207^Application internal error^HL70357|E||||Message could not be accepted

Enhanced mode. When MSH-15 or MSH-16 is filled in, the same points answer CA, CE, or CR. Application-level acknowledgments are not sent.

Message types

Each interface lists the types it may send. Anything else is refused with AR.

MessageUseWhat ChartVoyant does
ORU^R01Lab resultsFiles a diagnostic report and its observations for the matched patient, marked not yet reviewed, and opens one inbox item for the ordering clinician.
ORU^R01Radiology & narrative reportsFiles the report text as a radiology report, stores an embedded PDF when sent, and opens an inbox item.
ADT^A01, A04, A03Admit, register, dischargeRecords a hospital event, separate from the practice's own visits, with an inbox notice. Discharge notices are high priority.
ADT^A08, A28, A31Demographic updatesWrites a proposal. Nothing on the chart changes until staff accept it field by field.
ADT^A11, A13Cancel admit, cancel dischargeMarks the earlier event cancelled. Nothing is deleted.
ADT^A40MergeBecomes a notice for staff. Charts are never merged from a message.
ORM, MDM, VXU & othersNot supportedRefused with AR and ERR 200 or 201.

One ORU can carry results for several patients; each PID group is matched and filed independently. An ADT carries one patient: a second PID makes the whole message AE.

After the ACK

  • Matching is strict. A result files on its own only when PID-3 carries an identifier the practice has already confirmed for your feed and the birth date agrees, or when your placer order number (ORC-2 or OBR-2) is a ChartVoyant order whose patient has the same birth date and family name. Anything less goes to a review queue with the evidence. PID-19 is ignored.
  • Never a new patient, never a merge. An unmatched message writes nothing to any chart. Staff pick the patient, or mark the message not theirs.
  • The lab's flags stay the lab's. OBX-8 is shown as sent. When empty, no flag is fabricated from the reference range.
  • Corrections are tracked. A corrected result (C in OBR-25 or OBX-11) keeps the earlier version, opens a new high-priority inbox item, and clears the earlier review. D or W marks a result as removed by the lab.
  • Attachments. An embedded PDF (OBX-2 ED) is stored with the report. A reference pointer (RP) is never fetched.
  • Patients see results on the practice's usual schedule. Review does not delay the patient portal. A clinician can hold one result at a time under 45 CFR 171.201, with the reason recorded.
  • No AI on results in production. A descriptive summary beside the lab's values exists for test environments only. The lab's values are never changed.
  • Every message is kept. The raw message is archived, encrypted, for ten years. Staff can replay a message that failed, and a replay never files a result twice.

Authentication

One credential per interface, bound to it when set up. A staff sign-in and a self-serve sandbox key are never accepted.

CredentialHow it works
HL7 sender keyAuthorization: Bearer cvk_…. Issued with a single permission: delivering HL7 to the interface it is bound to. It cannot read or write anything else, and ordinary read-only and full-access API keys cannot deliver HL7.
SMART Backend ServicesGet a token from https://auth.chartvoyant.com/oauth/token with client_credentials, a private_key_jwt assertion signed RS384 or ES384, and scope=system/hl7v2-ingest. Granted only to a backend client registered for it at that practice. See SMART Backend Services.
Request signingAn extra HMAC check (X-CV-Timestamp and X-CV-Signature) is defined but not offered yet. Do not send those headers: until a signing secret is set up for your interface, requests carrying them are refused with 401.
Mutual TLSNot available.

Limits

LimitValue
Message size2 MiB per request body (larger returns HTTP 413).
Rate, per interface20 messages per second and 600 per minute. Past that, answers generic AE and stores nothing.
Messages per requestOne. Batch envelopes (FHS and BHS) are not supported.
ProfilesStrict: v2.5.1 and UTF-8. Tolerant: v2.3, 2.3.1, 2.4, 2.5, and 2.5.1, Latin-1 text, and embedded PDFs split across repetitions or segments. Both retain unknown Z-segments.

How to get connected

  1. Tell us about the feed

    Email info@chartvoyant.com with the practice, sender, message types, HL7 version, MSH-3 and MSH-4, assigning authority in PID-3, expected volume, any intermediary, and a technical contact. Send no patient data.

  2. Sign the agreements

    Sign the HL7 v2 Interface Agreement online at e-sign.chartvoyant.com, plus a separate business associate agreement (and one for any intermediary in the path).

  3. We set up the interface

    Your credential, expected MSH values, processing ID, and message types are bound to that practice and delivered to your technical contact.

  4. Test with synthetic messages

    Testing runs on a separate interface in a ChartVoyant sandbox office with processing ID T and synthetic patients until every message type answers AA.

  5. Go live

    The practice's production interface is enabled once every approval is on file and the practice confirms.

Not available yet

Not available yet
MLLP and SFTP

Messages arrive over HTTPS only. MLLP over TLS or VPN, and SFTP file pickup, are not built.

Not available yet
Orders, documents and vaccines

ORM, MDM, and VXU messages are refused. Results and hospital events are the scope today.

Not available yet
HL7 out of ChartVoyant

ChartVoyant does not send HL7 v2. To receive data from a practice, see FHIR write to other systems.